OPTIFLEX 7200

Guided radar (TDR) level transmitter for advanced liquid applications

  • Continuous level and interface measurement in process or storage tanks, reactors and pressure vessels
  • Extensive choice of probes for harsh process conditions
  • Measuring range: 0.3…60 m / 1…197 ft
  • -50…+250°C / -58…+482°F; -1…100 barg / -14.5…1450 psig
OPTIFLEX 7200

Overview

The OPTIFLEX  7200 is a 2-wire guided radar level transmitter based on the Time Domain Reflectometry (TDR) technology. With its large choice of probe types and materials, this level transmitter is the high-end guided radar for level and interface measurement in the chemical or oil and gas industries. It is suitable for storage or process tanks up to 60 m / 196.85 ft, containing all kind of liquids – from hydrocarbons like slop oil or benzene to solvents and acids to cooling water or condensate.

The OPTIFLEX 7200 can be used at extended temperature and pressure conditions. Various converter and electronic versions like a remote converter or a sensor extension facilitate the access to the device. The level transmitter has approvals for use in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Extensive choice of probes for all applications:
    • Ø42 mm / 1.65″ coaxial probe made of 316L or HC22
    • Fully TFM-T62 PTFE-coated rod
    • Special materials available on request e.g. Monel®, tantalum, titanium, duplex
  • Ceramic process seal system for demanding process conditions
  • Reversed interface measurement
  • Patented Dynamic Gas-phase Compensation (DGC) without increased blocking distance (in preparation)
  • Various converter and electronic versions to facilitate access to the device:
    • Available as compact version (C) or with remote converter (F) up to 100 m / 328 ft
    • Sensor extension with compact version (S) up to 15 m / 49.2 ft
    • Double sensor extension with remote version (D) up to 115 m / 377.3 ft
    • Horizontal or vertical housing to suit every installation
  • Converter is rotatable and removable under process conditions and compatible with all previous Guided Radar (TDR) level transmitters made by KROHNE
  • Stainless steel housing for corrosive environment
  • Weather protection – protects the converter in extreme weather conditions
  • Diagnosis functions according to NAMUR  NE 107
  • NACE design MR 0175 (ISO 15156), MR 0103 (ISO 17945) / ASME B31.3
  • SIL 2/3
  • ±2 mm /±0.08″ accuracy
  • Real-time clock for event logging
  • 3-year warranty

General

  • Level and interface measurement of liquids in storage and process applications
  • Reversed interface measurement (e.g. water / tar)
  • Installation on magnetic level indicators (MLI) or in bypass chambers

Chemical and petrochemical industry

  • Ethylene, propylene, additives, corrosion inhibitors, butadiene
  • Solvents, alcohols, acids, bases
  • Benzene, hydraulic oil, fuels, biodiesel
  • Foaming agents
  • Level control on CO2 skids

Oil and gas industry

  • Slop oil, biodiesel, benzene, fuels, lubricant oil, various other hydrocarbons
  • Liquefied gases, condensates

Power generation

  • Hydraulic oil, lubricant oil
  • Fuel control of emergency generators
  • Cooling water, condensates
  • Lime milk

Metals industry, minerals and mining industry

  • Water tar mixtures

Specifications

General information

Product typeLevel transmitter
Product family nameOPTIFLEX
Product positioningFor advanced liquid applications
Measurement variablesDistance, Level, Mass, Volume, Dielectric constant
Measurement principleGuided radar (TDR)
Level measurement typeContinuous measurement
Contact to measured mediumYes
Interface measurementYes
Measured mediaLiquids, Liquid/liquid interface
Measuring range (liquids)0.3…60 m/
0.98…196.85 ft
Probe length0.3…60 m
0.98…196.85 ft
Probe diameter
  • Single cable Ø4 mm / 0.16″
  • Single rod Ø8 mm / 0.32″
  • Single rod Ø8 mm / 0.32″ (segmented)
  • Single rod (PTFE coated) Ø10 mm / 0.39″
  • Double rod Ø8 mm / 0.32″
  • Double cable Ø4 mm / 0.16″
  • Coaxial Ø22 mm / 0.87″
  • Coaxial Ø22 mm / 0.87″ (segmented)
  • Coaxial Ø42 mm / 1.65″
  • Reversed interface probe Ø10 mm / 3.9″
Measuring pointPressurised tank, Stilling well, Bypass

Operating conditions

Process pressure-1… 100 barg/
-14.5… 1450 psig
Process temperature-50…+250°C/
-58…+482°F

 

Materials

GasketsEthylene propylene diene monomer (EPDM), Fluoroelastomer rubber (FKM/FPM), Kalrez® 6375, Kalrez® 7075, Polytetrafluoroethylene (PTFE), Ceramic
Wetted partsAustenitic stainless steel (1.4404/316L), Austenitic alloy (2.4602/Alloy 22), Polytetrafluoroethylene (PTFE), Ceramic

 

Process connections

Flange connectionsEN (1092-1): DN25…200/
ASME (B 16.5): 1…8”/
JIS (B 2220): 40…200A
Thread connectionsMale:
G¾, G1, G1½
¾ NPT, 1 NPT, 1½ NPT

 

Approvals/Standards

Certificates/Approvals OthersNACE
Certificates/Approvals ExATEX, cQPSus, IECEx, NEPSI, INMETRO
Certificates/Approvals SafetySIL 2/3
Ingress protectionIP66/68, NEMA4X/6P
NAMUR complianceNE 107, NE 21, NE 43, NE 53

 

Communication

Analogue outputs4…20 mA
Discrete outputsRelay
Digital outputsHART®

 

Accuracy

Accuracy (liquids)±2 mm/
±0.08 in

 

Scroll to Top