OPTIFLUX 2050

Electromagnetic flowmeter for basic water and wastewater applications

  • Liner materials resistant to low concentrated chemicals
  • With extra isolation of electronics for use in high humidity areas
  • Flange: DN25…1200 / 1…48″, max. PN40 / ASME Cl 300
  • 4…20 mA, pulse, frequency, status, HART®, Modbus
OPTIFLUX 2050

If you need a large number of different models, you can contact me at any time. I will communicate with you as soon as possible to solve your problem.

Overview

The OPTIFLUX 2050 is an electromagnetic flowmeter (EMF) for basic water and wastewater applications. It is suitable for all cost-effective measurements where extremely high accuracy, extensive diagnostics or a wide range of communication options are not a priority. The EMF has a wide diameter range (DN25…1200 / 1…48″) and all drinking water approvals. The extra isolation of the electronic device and housing makes this EMF particularly suitable for use in areas with extreme humidity.

The OPTIFLUX 2050 features a full bore design with wear resistant liner materials. Installation in measurement chambers subject to (constant) flooding is possible with the IP68 / NEMA 6P rated version. The EMF comes with current output (incl. HART®) or active pulse/frequency output and Modbus. A full on-site verification of the OPTIFLUX 2050 without process interruption can be carried out using the OPTICHECK service tool.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Bi-directional flow measurement over a wide dynamic range
  • Tropicalized electronics for use in areas with extreme humidity and chances of flooding
  • Standard wet calibration
  • PP or hard rubber liner: excellent chemical resistance
  • Also available in customer specific constructions
  • Signal converter with display or as blind version
  • Tamper proof
  • Full bore design: No moving parts, no wear, no pressure loss
  • Meets potable water standards: ACS, DVGW, NSF, TZW, WRAS etc.
  • On-site verification of flowmeter with OPTICHECK service tool

General

  • All simple water and wastewater applications

Water and wastewater industry

  • Abstraction and irrigation
  • Monitoring of distribution networks
  • Water circulation and treatment systems
  • Water purification and desalination

Specifications

General information

Product typeFlowmeter
Product family nameOPTIFLUX
Product positioningFor basic water and wastewater applications
Measurement principleElectromagnetic
Measured mediaLiquids

Operating conditions

Process pressuremax. 40 barg/
580 psig
Process temperature-5…+90°C/
+23…+194°F

Materials

LinerPolypropylene (PP), Hard rubber

Process connections

Flange connectionsEN (1092-1): DN25…1200
ASME (B 16.5): 1…48″
JIS (B 2220): 25…1000A

Approvals/Standards

Certificates/Approvals MarineABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Certificates/Approvals Potable WaterDVGW, NSF, TZW, KTW, WRAS, KIWA, ACS

Communication

Analogue outputs4…20 mA
Discrete outputsPulse, Frequency, Status
Digital outputsHART®, Modbus RTU

Delivery Time

The general delivery cycle is : 4-6 weeks.

*Note: If you order a large quantity and variety of products, the delivery cycle may be extended appropriately.

If you have special requirements for the product, you can inform me through online chatemailWhatsApp, or any other method, and we will contact you within the same day to address your concerns.