OPTIMASS 1400

Coriolis mass flowmeter for universal applications and process control

  • Mass, density and volume flow of gases and liquids; maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4″, max. PN100 / ASME Cl 600; many hygienic fittings
  • 3 x 4…20 mA, HART®7, FF, Profibus-PA/DP, Modbus, PROFINET, EtherNet/IP™, Bluetooth®
OPTIFLUX 4100

If you need a large number of different models, you can contact me at any time. I will communicate with you as soon as possible to solve your problem.

Overview

The OPTIMASS 1400 is a cost-effective twin straight tube Coriolis mass flowmeter for a wide range of standard applications with gases and liquids (up to 170,000 kg/h or 6,235 lb/min). The meter features Entrained Gas Management (EGMTM) for liquid applications and thus maintains operation even with entrained gas of up to 100%.

The OPTIMASS 1400 features an optimised flow splitter for minimum pressure loss and can be drained and cleaned easily. Next to flange process connections it supports a wide range of standard hygienic connections for food and beverage applications. Like with all other KROHNE Coriolis mass flowmeters there are no installation restrictions as the OPTIMASS 1400 is not affected by crosstalk/line vibrations and can thus be installed in series or in parallel. It is also approved for use in hazardous areas. The Coriolis mass flowmeter provides enhanced diagnostics (NE 107) and comes with various digital communication options. Via the OPTICHECK Flow Mobileapp all device settings can be managed on-site via a secure Bluetooth® connection. In this way, a variety of commissioning tasks, e.g. zero calibration or configuration of diagnostics, can be done wirelessly.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Twin straight tube design
  • Entrained Gas Management (EGMTM): meter maintains operation with air or gas entrainments in the medium
  • Device commissioning, verification, diagnostics and monitoring via a secure wireless Bluetooth® connection (<20 m / 65.6 ft)
  • Fast and completely digital signal processing
  • Best-in-class price/performance ratio
  • High accuracy mass, density and volume flow measurement (±0.15% of MV)
  • Extensive sensor and process diagnostics (incl. NE 107)
  • Integrated temperature measurement
  • Optimised flow splitter for low pressure loss
  • Optional PED approved secondary pressure containment up to 100 barg / 1450 psig
  • Optional insulation, heating jacket or purge ports
  • No crosstalk: resistant to installation and process effects
  • On-site verification of flowmeter with OPTICHECK service tool

General

  • Standard process applications up to 130°C / 266°F
  • Measurement of liquids, gases and gas entrained liquids
  • Portable installations on trucks, rail tankers, portable rigs etc.
  • Applications with very low operating densities (<10 kg/m3)

Food and beverage industry

  • Measurement of flow, density, specific gravity in brewing processes
  • Flow measurement of beverages and fruit juices
  • Dairy products
  • Fat, oily and greasy products
  • Dosing of additive food components

Pharmaceutical industry

  • Batching, dosing, filling
  • Solvent extraction
  • Ultrapure water ring-main measurement

Chemical and other process industries

  • Bulk loading
  • Batching to reactors

Marine industry

  • Fuel consumption measurement

Pulp and paper industry

  • Batching and dosing of additives, bleaches and colourants

Water and wastewater industry

  • Flocculant dosing

Specifications

General information

Product typeFlowmeter
Product family nameOPTIMASS
Product positioningFor universal applications and process control
Measurement principleCoriolis
Measured mediaLiquids, Gases

Operating conditions

Process pressuremax. 100 barg/
1450 psig
Process temperature-40…+130°C/
-40…+266°F

 

Materials

Measuring tubeDuplex stainless steel (1.4462/318)

 

Process connections

Flange connectionsEN (1092-1): DN15…100
ASME (B 16.5): ½…4″
JIS (B 2220): 15…80A
Hygienic connectionsClamp (DIN 32676): DN25, DN40, DN50, DN80
Clamp (ISO 2852): 25, 40, 51, 76.1
Tri-Clamp: 1″, 1½”, 2″, 3″
Threaded ferrule (DIN 11851): DN25, DN40, DN50, DN80
Flange with groove (DIN 11864-2): DN25, DN40, DN50, DN80
Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm, 76 mm

 

Approvals/Standards

Certificates/Approvals OthersNACE
Certificates/Approvals ExATEX, IECEx, NEPSI, EAC Ex, cFMus, INMETRO, KCs, UKEX
Certificates/Approvals HygienicFDA, 3A, EHEDG, EC 1935/2004
Certificates/Approvals MarineABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS, RS
Certificates/Approvals NuclearNuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.)

 

Communication

Analogue outputs4…20 mA
Discrete outputsLimit switches, Pulse, Frequency, Status
Digital outputsFOUNDATION™ fieldbus, HART®, Profibus-PA, Profibus-DP, Modbus RTU, EtherNet/IP™, PROFINET, Bluetooth

 

Delivery Time

The general delivery cycle is : 4-6 weeks.

*Note: If you order a large quantity and variety of products, the delivery cycle may be extended appropriately.

If you have special requirements for the product, you can inform me through online chatemailWhatsApp, or any other method, and we will contact you within the same day to address your concerns.

Please enable JavaScript in your browser to complete this form.
Scroll to Top