VA40

Variable area flowmeter for basic applications

  • With glass tube, MIN/MAX switches and 4…20 mA
  • Low pressure loss for gas applications
  • Flange: DN15…50 / ½…2″; also NPT, G, hygienic connections, etc.
  • -20…+100°C / -4…+212°F; max. 10 barg / 145 psig
VA40

Overview

The VA40 is a glass tube variable area (VA) flowmeter for flow measurement of liquids and gases. The all-purpose flowmeter is suitable for all basic applications up to +100°C / +212°F and max. 10 bar / 145 psi. Typical applications include flow measurement of flushing, purging or inert gases or heating and cooling circuits.

The VA40 operates without auxiliary power supply. The measuring cone, protected by a metal sleeve with a viewing glass, makes it easy to directly read the flow and to observe the medium. The VA meter can also be equipped with two optional limit switches (MIN/MAX) or analogue output (4…20 mA). The flowmeter comes with many process connections and can be used in hazardous areas.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Simple, low-cost measuring principle without auxiliary power
  • For direct reading of the flow and observation of the medium
  • Optional MIN/MAX flow switches (SIL 2 conform acc. to IEC 61508-2) or 4…20mA for recording and control
  • Full scale value for liquids: 0.4…10,000 l/h / 0.1…2,650 GPH
  • Full scale value for gases: 7…310,000 l/h / 0.25…11,000 SCFH
  • Maximum measuring error: ±1% (acc. to VDI/VDE 3513-2) or ±1% of full scale
  • Turndown ratio 10:1
  • Use in hazardous areas
  • Suitable for use in Safety Instrumented Systems with SIL 2, in redundant design (1oo2) also in SIL 3 applications (type A device)
  • Available as food and pharmaceutical variant (with FDA compliant materials)

Machinery and apparatus (OEM industry)

  • Air and cooling water supply
  • Gas measurement for industrial furnaces and thermal processes
  • Measurement of protective gases

Pharmaceutical industry

  • Demineralised and ultrapure water, alcohol, solvents, insulin etc

Food and beverage industry

  • Air or water supply, alcohol, nitrogen, carbon dioxide (CO2)

Conventional and nuclear power industry

  • Water monitoring in auxiliary circuits

Specifications

General information

Product typeFlowmeter
Product family nameVA
Product positioningFor basic applications
Measurement principleVariable area float
Measured mediaLiquids, Gases

Operating conditions

Process pressuremax. 10 barg/
145 psig
Process temperature0…+100°C/
+32…+212°F

Materials

Measuring tubeBorosilicate glass
GasketsEthylene propylene diene monomer (EPDM), Perfluoroelastomer rubber (FFKM), Fluoroelastomer rubber (FPM), Nitrile butadiene rubber (NBR)
Process connectionAustenitic stainless steel (1.4404/316L), Polyvinylidene fluoride (PVDF), Chromised steel

Process connections

Flange connectionsEN (1092-1): DN15…50
ASME (B 16.5): ½…2″
Thread connectionsFemale:
G½, G¾, G1, G1½, G2
½ NPT, ¾ NPT, 1 NPT, 1½ NPT, 2 NPT
Other connectionsHose: DN15, DN25, DN40, DN50
Hygienic connectionsClamp (DIN 32676): DN15, DN25, DN40, DN50
Clamp (ISO 2852) 17.2, 25, 40, 51
Tri-Clamp: ½”, 1″, 1½”, 2″
Threaded ferrule (DIN 11851): DN15, DN25, DN40, DN50
Threaded ferrule (SMS 1146): 25 mm, 38 mm, 51 mm

Approvals/Standards

Certificates/Approvals ExATEX, UKEX
Certificates/Approvals HygienicFDA, EC 1935/2004
Certificates/Approvals NuclearNuclear qualification on request (e.g. acc. to ASME III, RCC-M/E, etc.)
Certificates/Approvals SafetySIL 2

Communication

Analogue outputs4…20 mA
Discrete outputsLimit switches
Scroll to Top